產(chǎn)品簡(jiǎn)介

fjrigjwwe9r1dt_article:contentSensyflowFMT500-IGisadigitalmassflowmeterforair,gasesandgasmixturesinprocessapplications

詳細(xì)介紹

fjrigjwwe9r1dt_article:content

Sensyflow FMT500-IG is a digital mass flow meter for air, gases and gas mixtures in process applications. The system is supplied with LCD display, integrated gas temperature measurement and totalizer functions. Communication and configuration is via the PROFIBUS DPV1 protocol or analog output / HART . Compact and remote versions allow for flexible mounting solutions. ATEX certified versions for Zone 0 and 1 applications are available.

  • Digital measuring system
  • PROFIBUS DPV1 or HART communication
  • Separate gas temperature measurement
  • Diagnostic functions
  • ATEX certification for Zone 0 and 1(gases) and 21 (dust)
fjrigjwwe9r1dt_article_attribute_value:technicalparameters
2 Specifications
Type FMT400-VTS FMT400-VTCS
Hygienic version
Measured variable (measured gases) Flow of gases and gas mixtures with known composition Flow of air, N2, CO2, O2
Measuring ranges
Nominal diameters (DN)
DN 25
DN 40
DN 50
DN 65
DN 80
DN 100
DN 125
DN 150
DN 200
Up to 3000 mm
qmin qmax
kg/h kg/h
0 ... 160
0 ... 430
0 ... 700
0 ... 1,200
0 ... 1,700
0 ... 3,000
0 ... 5,100
0 ... 8,000
0 ... 13,000
0 ... 2,700,000
qmin qmax
Nm3/h Nm3/h
For 0 °C (32 °F) /
1013.25 hPa (14.696 psia)
0 ... 120
0 ... 330
0 ... 540
0 ... 940
0 ... 1,300
0 ... 2,300
0 ... 3,900
0 ... 6,200
0 ... 10,000
0 ... 2,100,000
qmin qmax
kg/h kg/h
0 ... 160
0 ... 430
0 ... 700
0 ... 1,700
qmin qmax
Nm3/h Nm3/h
For 0 °C (32 °F) /
1013.25 hPa (14.696 psia)
0 ... 120
0 ... 330
0 ... 540
0 ... 1,300
(rectangular ducts and larger diameters on request)
Measuring ranges
Nominal diameters (inch)
1,0
1,5
2,0
3,0
4,0
6,0
8,0
120,0
qmin qmax
lbs/h lbs/h
0 ... 310
0 ... 840
0 ... 1,400
0 ... 3,500
0 ... 6,000
0 ... 16,500
0 ... 28,500
0 ... 6,000,000
qmin qmax
SCFM SCFM
For 15 °C (59 °F) /
1013.25 hPa (14.696 psia)
0 ... 65
0 ... 180
0 ... 310
0 ... 760
0 ... 1,300
0 ... 3,600
0 ... 6,200
0 ... 1,300,000


(rectangular ducts and larger diameters on request)
Notes regarding measuring ranges The above values are reference values for applications involving air or nitrogen under atmospheric conditions (other gases available upon request).
The values for qmax can be increased by approx. 10 % upon request (with lower accuracy in the extended range).
With hydrogen and helium, the lower range limit is typically approx. 10 % of the upper range limit.
Measuring errors
Air, nitrogen other gases
Under calibration conditions in specified measuring range
± 0.9 % of the measured value ± 0.05 % of the possible end value in this nominal diameter (see measuring ranges)
± 1.8 % of the measured value ± 0.10 % of the possible end value in this nominal diameter (see measuring ranges)
Special calibration on request
Reproducibility < 0.25 % of the measured value, tmeas = 10 s
Effect of the temperature of the measured medium < 0.05 % / K of the measured value (depending on the type of gas)
Effect of the pressure of the measured medium < 0.2 % / 100 kPa (/ bar) of the measured value (depending on the type of gas)
Response time T63 = 0.5 s T63 = 2 s
Type FMT400-VTS FMT400-VTCS
Hygienic version
Operating conditions
Recommended steadying lengths According to DIN EN ISO 5167-1 Min. inflow 15 x D, outflow 5 x D
Ambient conditions
Transmitter ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Zone 2/22 version: -20 ... 50 °C (-4 ... 122 °F)
CIP/SIP cleaning - With device switched off
Storage temperature -25 ... 85 °C (-13 ... 185 °F)
Process conditions
Operating temperature of measured medium (flowmeter sensor) Standard range: -25 ... 150 °C (-13 ... 302 °F)
Extended range: -25 ... 300 °C (-13 ... 572 °F)
Zone 2/22 version: -20 ... 130 °C (-4 ... 266 °F)
-25 ... 150 °C (-13 ... 302 °F)
Operating pressure 4 x 106 Pa (40 bar [580 psi]) 1.6 x 105 Pa (16 bar [232 psi]) threaded pipe connection S
(for DN 80: 10 x 105 Pa (10 bar [145 psi]))
10 x 105 Pa (10 bar [145 psi]) FG flange
Pressure drop
(logarithmic representation)
Pressure drop [mbar] →
G00796
Power supply
Voltage
Power consumption
24 V DC ± 25 %; 24 V AC ± 25 %, 48 ... 62 Hz
< 15 W, current consumption < 600 mA, minimum fuse protection 2 A time-lag
Cable entry M20 x 1.5
Output
Analog output 0/4 ... 20 mA, load < 750 Ω, electrically isolated, failure message < 3.5 or > 22 mA
Degree of protection IP 65, NEMA 4X
< 1.0 kPa (10 mbar), typical value 0.1 kPa (1 mbar)
DN 25
#
5
DN 50 DN 80 DN100
DN 150
1
5
1
10 50 100 500 10000

其他推薦產(chǎn)品

更多

收藏該商鋪

請(qǐng) 登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~

對(duì)比框

產(chǎn)品對(duì)比 二維碼

掃一掃訪問(wèn)手機(jī)商鋪
在線留言