Delivering reliable results that save you critical time and effort.
90 days of continuous runtime
Only two liters of reagent are required for the analyzer to
perform unattended for up to 90 days; twice as long as the
previous analyzer versions.
Save time on maintenance
The industry’s only pressurized reagent delivery system
eliminates the frequent maintenance associated with pumps.
Avoid downtime
Predictive diagnostic tools, including Hach’s proprietary
Prognosys technology, warning LEDs, and high-visibility
notification screens let you avoid unplanned downtime.
Verify easily with Hach Lab products so you
don’t waste time second-guessing
Grab Sample In and Grab Sample Out features allow quick
analysis of a grab sample poured into the analyzer, and
facilitate taking a sample out of the analyzer to verify in a lab test.
9610 sc Silica Analyzer—Technical Data
Measuring Principle Colorimetric
Range 0 to 5000 μg/L as SiO2
Accuracy :0 - 500 μg/L: ±1% or ±1 μg/L of reading, whichever is greater;
500 - 5000 μg/L: ±5%(Tested with Hach reagents)
Repeatability ± 0.5 μg/L or ±1% of reading, whichever is greater
Lower Limit of Detection (LOD) 0.5 μg/L
Response Time Typically, 9.5 minutes at 25 °C
(77 °F); changes with temperature
Reagent Consumption 2 L of each reagent every 90 days
with 15 minute cycle time
Operating TemperatureRange 5 - 45 °C (41 - 113 °F)
Operating Humidity 5 - 95% relative humidity, noncondensing (indoor use only)
Sample Pressure 2 - 87 psi (to Preset Pressure Regulator)
Sample Temperature 5 - 50 °C (41 - 122 °F)
Sample Flow Rate 55 - 300 mL/min
Number of Channels 1, 2, 4, 6; programmable sequence
Grab Sample Grab Sample In and Grab Sample
Out capability
Mounting Wall, panel or table
9610 sc Silica Analyzer—Fitting Type Sample line and sample bypass
drain: 6 mm (¼-in.)
Air purge inlet: 6 mm (¼-in.)
Chemical and case drains: 9.5 mm (3/8-in.)
Power Requirements (Voltage)100 - 240 V AC, 24 V DC
Power Requirements (Hz) 50/60 Hz
Output 4 - 20 mA
Dimensions (H x W x D) 804 mm x 452 mm x 360 mm
Enclosure Rating IP56 / NEMA 4X
Certifications CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991,
+A1:2000),KC (EN 61326-1: 2006) C-tick (EN 61326-1: 2006) cETLus (UL 61010-1: 2012; NEMA 250: 2003; CSA C22.2 No 61010-1: 2012)
*Subject to change without notice.
Silica in the sample reacts with molybdate ions under acidic conditions to form silicomolybdic acid complexes. Addition of citric acid
destroys the phosphate complexes. Amino acid reagent is then added to reduce the yellow silicomolybdic acid to an intense blue
color, which is proportional to the silica concentration. Test results are measured at 815 nm.
9610 sc Silica Analyzer—Instruments
9610.KTO.S0.A1U 9610 sc Silica Analyzer, open chemistry, 1 channel, 100-240 VAC
9610.KTO.S0.A2U 9610 sc Silica Analyzer, open chemistry, 2 channels, 100-240 V AC
9610.KTO.S0.A4U 9610 sc Silica Analyzer, open chemistry, 4 channels, 100-240 VAC
9610.KTO.S0.A6U 9610 sc Silica Analyzer, open chemistry, 6 channels, 100-240 VAC
9610.KTO.S0.D1U 9610 sc Silica Analyzer, open chemistry, 1 channel, 24 VDC
9610.KTO.S0.D2U 9610 sc Silica Analyzer, open chemistry, 2 channels, 24 VDC
9610.KTO.S0.D4U 9610 sc Silica Analyzer, open chemistry, 4 channels, 24 VDC
9610.KTO.S0.D6U 9610 sc Silica Analyzer, open chemistry, 6 channels, 24 VDC
Each Analyzer comes with a Hach reagents set for start up and up to 90 days of use
9610 sc Silica Analyzer—Reagents
sc Silica Reagent Set
sc Reagent 1 Silica, 2 L
sc Reagent 2 Silica, 2 L
sc Standard 1 Silica, 2 L
sc Reagent 3 Silica, Package
sc Reagent 4 Silica, 2 L
9610 sc Silica Analyzer—Accessories/Options
6786600 Stainless steel sample adapter kit
1757700 Stainless steel sample cooler
6792501 Module kit, Modbus (SC200)
6792601 Profibus DP Module
9610 sc Silica Analyzer—sample